Logic 3.0 Technology (L3)
Added
Value
-
Built-in
3-channel, 315MHz radio receiver accepts up to
23 Security+® or unlimited DIP switch remotes.
3-button remotes can be programmed for
open/close/stop operation.
-
Maintenance Alert System™ establishes a routine
maintenance schedule based on the number of
cycles or calendar date. Includes
self-diagnostic system that allows you to
troubleshoot up to eight different error codes.
-
Timer-to-Close allows programming in 5-sec or
1-min increments. Commercial or industrial
photo-eyes required.
-
Thermal
motor overload can be easily reset from the
3-button floor level control station
Reliability &
Programming Simplicity
-
Switchless motor eliminates stuck start switch
and motor malfunctions on single-phase operators
-
All
high-voltage connections have been removed from
the board for safety and ease of service
-
Diagnostic LEDs speed installation and
troubleshooting
-
Motor
direction jumper lets you change motor direction
by simply moving a jumper
Mechanical Reversing Contactor Circuit (M):
(115V, 208/230V, 460V, 575V, 24V NEC Class 2 Circuit
with 40VA transformer) Industrial linear contactor
provides significantly longer control runs than
conventional contactors.
Standard Features
Motor:
Continuous-duty high-starting torque motor with instant
reverse and overload protection. Available in 1/3, 1/2,
3/4 and 1 HP; single- or three-phase. Removable without
affecting limit switch settings.
Drive Reduction: First-stage
heavy-duty 5L V-belt; second and third stages #48 chain;
#50 drive chain.
Emergency Disconnect: Easy emergency
manual operation using an electrically interlocked floor
level disconnect.
Wiring Type: B2, C2, D1 and E2 wiring
types are standard and easily set using a selector dial
on the Logic 3.0 Control Board (L3). T and TS wiring can
be activated with use of a CPS-L or CPS-LN4. Reversing
Contactor Units (M) have C2 wiring standard and B2
available by simply moving a jumper wire. Operators are
pre-wired to accept a sensing edge, photoelectric
sensors, radio controls and most types of access control
equipment. Failsafe wiring can be selected with use of a
CPS-L, CPS-LN4 or failsafe edge and CPS3 card.
External Radio Control Terminal:
Quick, convenient connections for retrofitting or
adding radio controls on logic or mechanical operators.
Bearings: Industrial ball bearings on
a 1" output shaft; heavy-duty oil-filled iron bearings
on reduction shafts.
Friction Clutch: Adjustable, helps
protect against major damage to door and operator should
the door meet an obstruction.
Construction: NEMA 1 type electrical
box, heavy-duty 11-gauge steel frame with durable
powdercoat finish, all reduction sprockets drilled and
pinned to shafts.
Push Button Station: 3-button station
comes standard and has open/close/stop functionality.
Positive Locking Mechanical Brake System:
Self-locking mechanical reduction system that functions
as a holding brake.
Control
Accessories
CPS®
Commercial Protector System®: (recommended) A
“non-contact” photo safety sensor designed to sense an
obstruction and signal the door operator to reverse to
open.
Sensing Edge: (recommended) Designed
to sense an obstruction and signal door operator to stop
or reverse as desired. An electric or pneumatic sensing
device can be added to bottom edge of door.
Emergency Egress Device: Faceplate
mounts flush on wall and contains pull handle to
disconnect operator from grille. Allows the door to be
opened manually or by spring tension.
Available Plug-in
Options for Logic 3.0 (L3)
Auxiliary
Contact: Used to operate security, warning,
heating or other 5V to 240V devices. Features both
normally open and closed contacts that actuate in
conjunction with limit switches.
Warning Signal: Red/green light
module provides safety warning prior to close (when
using timer-to-close feature). Also supports audio
warning devices and includes down mid-stop feature.
CPS3 Option: Enables the addition of
a second set of photo-eyes or 2- or 4-wire,
self-monitoring edge. |
 |