Doorking 9000 1/2hp  115V Primary Slide Gate Operator 9000-080

Doorking 9000 1/2hp 115V Primary Slide Gate Operator 9000-080

Call for price

ACCESSORIES & RELATED MODELS

Doorking 9000 Post Mount Kit  for model 9000 Slide Gate Operator 9000-015

Doorking 9000 Post Mount Kit for model 9000 Slide Gate Operator 9000-015

Doorking 9000-015 Post Mount Kit for the model 9000 Slide Gate Operator only...

Reno PLB-24-50-RA Preformed Loop (4' X 8' X 50 ft lead-in from corner)

Reno PLB-24-50-RA Preformed Loop (4' X 8' X 50 ft lead-in from corner)

Application: 1/4" wide saw cuts, gated facilities The Model PLB Preformed Loop is a prefabricated loop/lead-in assembly designed to be installed in 1/4“ wide saw cuts. The design allows for variations in the perimeter of the loop slot. There is no need for 45 degree corner cuts. The PLB loop cable, lead-in cable, and splice enclosure are designed for maximum reliability and long life. Wire insulation and cable jackets are Cross-linked Polyethylene (XLPE). XLPE insulation provides e..

Linear AK-11 Exterior Digital Keypad  ACP00748

Linear AK-11 Exterior Digital Keypad ACP00748

The Model AK-11 Exterior Digital Keypad is a digital keyless entry system designed for access control applications. The keypad is housed in a rugged cast aluminum enclosure that can be mounted to a pedestal or bolted directly to a wall. The die-cast keys have bright, easy-to-read yellow graphics. Up to 480 entry codes, from 1 to 6 digits in length, can be programmed. They can activate either, or both, of the relay outputs. Relay #1 has a 5 Amp capacity. Relay #2 has a 1 Amp capacity. The rela..

Doorking 2600 High Voltage Kit. Required to upgrade Voltage from 115vac 2600-266

Doorking 2600 High Voltage Kit. Required to upgrade Voltage from 115vac 2600-266

Allows the operator to be powered from 208,230,460 or 575 source-voltage. In dual gate applications, only one (1) kit is required (secondary operator DOES NOT require a high voltage kit)...

Doorking 9409 Plug-in 2 channel Loop Detector 9409-010

Doorking 9409 Plug-in 2 channel Loop Detector 9409-010

Click on the "Related Products" Tab Above for More Models Loop detectors and loops are strongly recommended on all automated vehicular gate applications to help prevent gates from closing on vehicles in the path of the gate. DKS Single & Two-Channel Loop Detectors Model 9410-010 DKS Single Channel Loop Detector Model 9409-010 DKS Two Channel Loop Detector Plug‐in detector ‐ use with DKS gate operators only Reno A&E Loop Detectors Model 9402‐045 Reno A..

Click on the "Related Products" Tab Above for More Models

The DKS 9000 series of slide gate operators offer convenience, reliability and safe operation in a small, compact design. These operators are ideally used in residential, commercial or industrial high-use applications. The steel frame and belt drive/gear-box reduction system provide a powerful, yet extremely quiet, slide gate operation. The 9000 uses an advanced microprocessor control circuit with outstanding features. Designed with versatility in mind, these operators will fit most slide gate operation requirements.

The model 9000 slide gate operator is designed to operate vehicular sliding gates in residential commercial and industrialapplications. The operator has a full feature circuit board and includes 20-feet of #40 chain.Secondary operators are usedin bi-parting (dual) gate applications and are commanded from and powered from the primary operator. Secondary operators cannot be used as a stand-alone device.
Features: 
  • Steel frame provides strength and quiet operation
  • “T-Handle” release is easily accessible from front of operator
  • Operator re-connects automatically when handle is released
  • Adjustable partial open limit
  • Direct driven limit nuts for precise gate control
  • Auto-close timer 1-30 seconds
  • Ports for plug-in open and reverse loop detectors – DKS detectors only
  • Selectable loop/reverse input function; stop or reverse
  • Anti-tailgating feature helps to control un-authorized traffic
  • Standard normally closed stop circuit
  • Gate Tracker reporting output provides operator data to DKS access control system
  • Convenience outlets for accessory transformers
  • Built-in power switch and alarm reset switch
  • Simple bi-parting gate interface

Specifications: 

Maximum gate width 35-ft.

Maximum gate weight 1000 pounds* (1/2 HP) or 1500 pounds* (1 HP). (*Assumes gate is on level ground, in good condition with properly adjusted hardware. Other external factors may affect the performance of the gate operator.)

1/2 or 1 HP continuous-duty motor

115, 230*, 208*, 460* VAC.  (*230, 208, and 460 volt units use a step-down power transformer to achieve 115 volt operating voltage.)

Class I, II, III and IV applications

Compliant with UL 325 and 991, ETL Listed. (Note: To be compliant with UL 325 and industry safety guidelines, additional secondary entrapment prevention devices are required to be installed with this gate operator. Your professional DKS system installer can provide you with more details on these devices and on current industry safety standards.)

Dimensions: 18.375"W x 31.675"H x 23.25"D

Options: 

Plug-in loop detectors.

Heater kit for cold environments.

Secondary entrapment prevention devices.

Bi‐parting gate connection cable.

Gate operator control stations

Postal and Fire Dept lock boxes

Surge suppressors, time clocks, trafic signal.

There are no reviews for this product.

Write a review

Note: HTML is not translated!
Bad           Good
Doorking 9000 Post Mount Kit  for model 9000 Slide Gate Operator 9000-015

Doorking 9000 Post Mount Kit for model 9000 Slide Gate Operator 9000-015

Doorking 9000-015 Post Mount Kit for the model 9000 Slide Gate Operator only...

Reno PLB-24-50-RA Preformed Loop (4' X 8' X 50 ft lead-in from corner)

Reno PLB-24-50-RA Preformed Loop (4' X 8' X 50 ft lead-in from corner)

Application: 1/4" wide saw cuts, gated facilities The Model PLB Preformed Loop is a prefabricated loop/lead-in assembly designed to be installed in 1/4“ wide saw cuts. The design allows for variations in the perimeter of the loop slot. There is no need for 45 degree corner cuts. The PLB loop cable, lead-in cable, and splice enclosure are designed for maximum reliability and long life. Wire insulation and cable jackets are Cross-linked Polyethylene (XLPE). XLPE insulation provides e..

Linear AK-11 Exterior Digital Keypad  ACP00748

Linear AK-11 Exterior Digital Keypad ACP00748

The Model AK-11 Exterior Digital Keypad is a digital keyless entry system designed for access control applications. The keypad is housed in a rugged cast aluminum enclosure that can be mounted to a pedestal or bolted directly to a wall. The die-cast keys have bright, easy-to-read yellow graphics. Up to 480 entry codes, from 1 to 6 digits in length, can be programmed. They can activate either, or both, of the relay outputs. Relay #1 has a 5 Amp capacity. Relay #2 has a 1 Amp capacity. The rela..

Doorking 2600 High Voltage Kit. Required to upgrade Voltage from 115vac 2600-266

Doorking 2600 High Voltage Kit. Required to upgrade Voltage from 115vac 2600-266

Allows the operator to be powered from 208,230,460 or 575 source-voltage. In dual gate applications, only one (1) kit is required (secondary operator DOES NOT require a high voltage kit)...

Doorking 9409 Plug-in 2 channel Loop Detector 9409-010

Doorking 9409 Plug-in 2 channel Loop Detector 9409-010

Click on the "Related Products" Tab Above for More Models Loop detectors and loops are strongly recommended on all automated vehicular gate applications to help prevent gates from closing on vehicles in the path of the gate. DKS Single & Two-Channel Loop Detectors Model 9410-010 DKS Single Channel Loop Detector Model 9409-010 DKS Two Channel Loop Detector Plug‐in detector ‐ use with DKS gate operators only Reno A&E Loop Detectors Model 9402‐045 Reno A..

File Name Size Link
Doorking 9000 Quickstart Manual 2.69Mb download
Doorking 9000 Spec Brochure 0.68Mb download
Doorking 9000 Post Mount Instructions 0.50Mb download
Doorking Loop Install Instructions 3.61Mb download